DRK-1000A Type Anti-blood-borne Pathogen Penetration Tester

Products Details

Test items: Penetration test against blood-borne pathogens This instrument is specially designed for testing the permeability of medical protective clothing against blood and other liquids; the hydrostatic pressure test method is used to test the penetration ability of protective clothing materials against viruses and blood and other liquids. Used to test the permeability of protective clothing to blood and body fluids, blood pathogens (tested with Phi-X 174 antibiotic), synthetic blood, etc. It can test the anti-liquid penetration performance of protective equipment including gloves, protective clothing, outer covers, coveralls, boots, etc. 1 Product Introduction This instrument is specially designed for testing the permeability of medical protective clothing against blood and other liquids; the hydrostatic pressure test method is used to test the penetration ability of protective clothing materials against viruses and blood and other liquids. Used to test the permeability of protective clothing to blood and body fluids, blood pathogens (tested with Phi-X 174 antibiotic), synthetic blood, etc. It can test the anti-liquid penetration performance of protective equipment including gloves, protective clothing, outer covers, coveralls, boots, etc. 2 Features ● Negative pressure experiment system, equipped with fan exhaust system and high efficiency filter for inlet and outlet to ensure the safety of operators; ● Industrial-grade high-brightness color touch screen; ● U disk export historical data; ● The pressure point pressurization method adopts fully automatic adjustment to ensure the accuracy of the test. ● The special stainless steel penetrating test tank guarantees the firm clamping of the sample and prevents the synthetic blood from splashing around; ● Imported pressure sensor is adopted, with accurate data and high measurement accuracy. Volume data storage, save historical experimental data; ● Built-in high-brightness lighting lamp in the cabinet; ● Built-in leakage protection switch to protect the safety of operators; ● The inner layer of the cabinet is integrally processed into stainless steel, and the outer layer is sprayed with cold-rolled plates, and the inner and outer layers are insulated and flame-retardant. 3 matters Needing Attention In order to prevent damage to your anti-blood-borne pathogen penetration tester experimental system, please read the following carefully before using this equipment. Keep this manual so that all product users can refer to it at any time. ① The operating environment of the experimental instrument should be well ventilated, dry, free of dust, and strong electromagnetic interference. ② The instrument should be powered off for more than 10 minutes if it continues to work for 24 hours to keep the instrument in good working condition. ③ Poor contact or open circuit may occur after long-term use of the power supply. Check and repair before each use to ensure that the power cord is not damaged, cracked, or open. ④ Please use a soft cloth and neutral detergent to clean the instrument. Before cleaning, make sure to disconnect the power supply. Do not clean the instrument with thinner or benzene or other volatile substances. Otherwise, the color of the instrument casing will be damaged, the logo on the casing will be wiped off, and the touch screen display will be blurred. ⑤ Please do not disassemble this product by yourself, please contact our company's after-sales service in time if you encounter any failure. 4 Appearance Structure and Corresponding Description 1. The front structure diagram of the host of the anti-dry microbial penetration test system, see the following figure for details: 1)Security door 2) 10-inch touch screen 3)Test system 4)Illumination lamp 5)Ultraviolet lamp 5 Main Technical Indicators
Main Parameter Parameter Range
Power Supply AC 220V 50Hz
Power 250W
Pressure Method Automatic Adjustment
Specimen Size 75×75mm
Clamp Torque 13.6N.M
Pressure Area 28.27cm²
Negative pressure range of negative pressure cabinet -50~-200Pa
High efficiency filter filtration efficiency Better than 99.99%
Ventilation volume of negative pressure cabinet ≥5m³/min
Data storage capacity 5000 groups
Host size (Length 1180×Width 650×Height 1300)mm
Bracket size (Length 1180×Width 650×Height 600)mm, height can be adjusted within 100mm
Total Weight About 150kg
6. Implementation Standards ASTM F 1670-1995. Standard Test Method for Resistance of Protective Clothing to Penetration of Artificial Blood ANSI/ASTM F1671-1996 Test method for testing the penetration rate of protective clothing materials against blood-borne pathogens with a virus penetration rate test system