DRK-880 18-Channel Pesticide Residue Detector

Multi-parameter food safety comprehensive detector adopts spectrophotometry, according to relevant national standards, can quickly detect the content of pesticide residues, formaldehyde, sulphur dioxide, nitrite, nitrate, etc. in food. It is suitable for fruits, vegetables, dry goods

Products Details

Channel pesticide residue detector, using enzyme inhibition, referring to national standards, can quickly detect pesticide residues in tested samples, and is widely used in organic phosphorus and carbamate pesticide residues in vegetables, fruits, grain, tea, water and soil The rapid testing is suitable for agricultural testing centers at all levels, production bases, farmer’s markets, supermarkets, hygiene, environmental protection, hotels, restaurants and other fields.
Wavelength  410nm±2nm
Inhibition rate measurement range  0-100%
Zero transmittance drift  0.5%/3min
Light current drift  0.5%/3min
Minimum detection limit  0.2mg/L(Methamidophos)
Transmittance accuracy  ±0.5%
Measurement repeatability  0.3%
Error of each channel  0.5%
Detection time  1min
Dimensions  360×240×110(mm)
Large screen true color touch screen The measurement speed is fast, the accuracy is high, and the fastest can be completed in one minute (the reaction time is freely set from 1-9 minutes)  Eighteen-channel test technology, multi-channel simultaneous Using semiconductor light source and detector, no moving parts, good repeatability, and the service life is tens of thousands of hours Provide car power interface, suitable for mobile office Automatically save the measurement results, and automatically print in Chinese Complete accessories, no need to purchase other equipment to detect Technology to prevent forged detection data Have a complete client program and food safety monitoring system Powerful network processing technology, computer can generate test report, and start network transmission immediately, and feed back to food safety test information network Communication interface: standard RS232 serial port or USB interfaceUnder certain conditions, organophosphorus and carbamate pesticides can inhibit the normal function of cholinesterase, and the inhibition rate is positively related to the concentration of the pesticide. Under normal circumstances, the enzyme catalyzes the hydrolysis of the nerve conduction metabolite (acetylcholine), and the hydrolyzed product reacts with the color reagent to produce a yellow substance. Use a pesticide residue detector to measure the absorbance change with time to calculate the inhibition rate, which can be judged by the inhibition rate Find out whether the sample contains organophosphorus or carbamate pesticides.

B. Technical Parameters

Product Description

Instrument Principle

A. Main features

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours